Industrial Controls & Automation

XCMD2102L1

XCMD2102L1 – Limit switch XCMD – steel roller plunger – 1NC+1NO – snap – 1 m

$112.00

Complementary
switch actuation
By 30° cam
electrical connection
Removable cable connector
cable length
1 m
cable composition
5 x 0.75 mm²
wire insulation material
PvR
contacts insulation form
Zb
positive opening
With
positive opening minimum force
35 N
minimum force for tripping
7 N
maximum actuation speed
0.5 m/s
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 V (pollution degree 3) conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V (pollution degree 3) conforming to CSA C22.2 No 14
maximum resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
IEC 60664 4 kV
IEC 60947-1 4 kV
short-circuit protection
6 A cartridge fuse, type gG
electrical durability
5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
mechanical durability
10000000 cycles
width
30 mm
height
50 mm
depth
16 mm
net weight
0.185 kg
Environment
shock resistance
25 gn for 18 ms conforming to IEC 60068-2-27
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
IP degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP68 conforming to IEC 60529
IK degree of protection
IK06 conforming to EN 62262
overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
ambient air temperature for operation
-25…70 °C
ambient air temperature for storage
-40…70 °C
protective treatment
TC
product certifications
CCC
CSA
UL
standards
EN/IEC 60204-1
UL 508
EN/IEC 60947-5-1
CSA C22.2 No 14