Industrial Controls & Automation

XCMD2110L1

XCMD2110L1  – Limit switch XCMD – metal end plunger – 1NC+1NO – snap – 1 m

$75.00

Main
range of product
OsiSense XC
series name
Standard format
product or component type
Limit switch
device short name
XCMD
sensor design
Miniature
body type
Fixed
head type
Plunger head
material
Metal
body material
Zamak
head material
Zamak
fixing mode
By the body
movement of operating head
Linear
type of operator
Spring return plunger metal
type of approach
Vertical approach, 1 direction
number of poles
2
contacts type and composition
1 NC + 1 NO
contact operation
Snap action
Complementary
switch actuation
On end
electrical connection
Removable cable connector
cable length
1 m
cable composition
5 x 0.75 mm²
wire insulation material
PvR
contacts insulation form
Zb
positive opening
With
positive opening minimum force
42.5 N
minimum force for tripping
8.5 N
minimum actuation speed
0.01 m/min
maximum actuation speed
0.5 m/s
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 V (pollution degree 3) conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V (pollution degree 3) conforming to CSA C22.2 No 14
maximum resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
IEC 60664 4 kV
IEC 60947-1 4 kV
short-circuit protection
6 A cartridge fuse, type gG
electrical durability
5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
mechanical durability
10000000 cycles
width
30 mm
height
50 mm
depth
16 mm
net weight
0.18 kg