Industrial Controls & Automation

View cart “6EP3332-6SB00-0AY0 LOGO! Power 24V / 2.5A ” has been added to your cart.

ABLS1A24031 | 100-240V AC, 24V 3.1 A

ABLS1A24031 Regulated Power Supply, 100-240V AC, 24V 3.1 A, single phase, Optimized

$65.00

Available on backorder

ABLS1A24031 – Main Characteristics
range of product Modicon Power Supply
product or component type Power supply
power supply type Regulated switch mode
variant option Optimized
enclosure material Plastic
Nominal input voltage 100…240 V AC single phase
100…240 V AC 2 phases
140…340 V DC
input voltage limits 85…264 V AC
120…375 V DC
rated power in W 75 W
output voltage 24 V DC
power supply output current 3.13 A
Complementary
Nominal network frequency 50…60 Hz
Network system compatibility TN
TT
IT
maximum leakage current 1 mA 240 V AC
input protection type Integrated fuse (not interchangeable) 5 A
External protection (recommended) 20 A Curve C
External protection (recommended) 13 A Curve B
External protection (recommended) 10 A Curve C
inrush current 40.0 A at 115 V
80.0 A at 230 V
power factor 0.55 at 115 V AC
0.45 at 230 V AC
efficiency 88 % at 230 V AC
Output voltage adjustment 21.6…26.4 V
power dissipation in W 15 W
current consumption < 1.8 A 115 V AC
< 1 A 230 V AC
< 0.8 A 140 V DC
Turn-on time < 1.2 s
holding time > 20 ms 115 V AC
> 40 ms 230 V AC
Startup with capacitive loads 5000 µF
residual ripple < 120 mV
Expected capacitor life time 10 year(s)
meantime between failure [MTBF] 700000 h at 25 °C, full load conforming to SR 332
output protection type Against overload and short-circuits, protection technology: automatic reset
Against over temperature, protection technology: manual reset
Against overvoltage, protection technology: manual reset
connections – terminals Screw connection: 0.5…2.5 mm², (AWG 20…AWG 14) for output
Screw connection: 0.75…2.5 mm², (AWG 18…AWG 14) for input
line and load regulation < 0.5 %line
< 1 %load
status LED 1 LED (green)output voltage
depth 102 mm
height 123.6 mm
width 27 mm
net weight 0.22 kg
output coupling Parallel
Serial
mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Double-profile DIN rail
supply SELV conforming to EN/IEC 60950-1
SELV conforming to EN/IEC 60204-1
SELV conforming to IEC 60364-4-41
Environment
standards EN 62368-1
EN/IEC 61010-1
EN 61010-2-201
EN/IEC 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
UL 62368-1
UL 61010-1
UL 61010-2-201
CSA C22.2 No 62368-1
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
EN/IEC 62368-1
product certifications CE
CUL listed
CUL recognized
RCM
CB Scheme
EAC
KC
NEC: class 2
environmental characteristic 3M4 conforming to IEC 60721-3-3
operating altitude < 5000 m
shock resistance 100 m/s² for 11 ms
IP degree of protection IP20
ambient air temperature for operation -20…-10 °C (with current derating of 1 % per °C)
40…70 °C (with current derating of 1.8 % per °C)
50…70 °C (with current derating of 2.5 % per °C)
ambient air temperature for storage -40…85 °C
relative humidity 0…95 % without condensation
overvoltage category II
electrical energy source class conforming to IEC 62368-1 ES1
electrical shock protection class Class I
pollution degree 2
vibration resistance 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6
10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic immunity Immunity to electrostatic discharge – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Immunity to electrostatic discharge – test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2
Immunity to conducted RF disturbances – test level: 10 V/m (80 MHz…2 GHz) conforming to EN/IEC 61000-4-3
Immunity to conducted RF disturbances – test level: 5 V/m (2…2.7 GHz) conforming to EN/IEC 61000-4-3
Immunity to conducted RF disturbances – test level: 3 V/m (2.7…6 GHz) conforming to EN/IEC 61000-4-3
Immunity to fast transients – test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
Surge immunity test – test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5
Surge immunity test – test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
Immunity to conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6
Immunity to magnetic fields – test level: 30 A/m (50…60 Hz) conforming to EN/IEC 61000-4-8
Immunity to voltage dips conforming to EN/IEC 61000-4-11
Disturbing field emission conforming to EN 55016-2-3
Limits for harmonic current emissions conforming to EN 61000-3-2
Conducted disturbance emission conforming to EN 55016-1-2
Conducted disturbance emission conforming to EN 55016-2-1
electromagnetic emission Conducted emissions conforming to EN 61000-6-3
Radiated emissions conforming to EN 61000-6-4
dielectric strength 3000 V AC input to output
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 301 g
Package 1 Height 3.7 cm
Package 1 width 14 cm
Package 1 Length 16 cm
Unit Type of Package 2 S03
Number of Units in Package 2 22
Package 2 Weight 7.29 kg
Package 2 Height 30 cm
Package 2 width 30 cm
Package 2 Length 40 cm