ABLS1A24031 Regulated Power Supply, 100-240V AC, 24V 3.1 A, single phase, Optimized
$115.00
ABLS1A24031
range of product | Modicon Power Supply |
---|---|
product or component type | Power supply |
power supply type | Regulated switch mode |
variant option | Optimized |
enclosure material | Plastic |
Nominal input voltage | 100…240 V AC single phase 100…240 V AC 2 phases 140…340 V DC |
rated power in W | 75 W |
output voltage | 24 V DC |
power supply output current | 3.13 A |
Input voltage limits | 85…264 V AC (without temperature derating) 120…375 V DC (without temperature derating) 85…120 V DC (with temperature derating) |
---|---|
Nominal network frequency | 50…60 Hz |
Network system compatibility | TN TT IT |
maximum leakage current | 1 mA 240 V AC |
input protection type | Integrated fuse (not interchangeable) 5 A External protection (recommended) 20 A Curve C External protection (recommended) 13 A Curve B External protection (recommended) 10 A Curve C |
inrush current | 40.0 A at 115 V 80.0 A at 230 V |
power factor | 0.55 at 115 V AC 0.45 at 230 V AC |
efficiency | 88 % at 230 V AC |
Output voltage adjustment | 21.6…26.4 V |
power dissipation in W | 15 W |
current consumption | < 1.8 A 115 V AC < 1 A 230 V AC < 0.8 A 140 V DC |
Turn-on time | < 1.2 s |
holding time | > 20 ms 115 V AC > 40 ms 230 V AC |
Startup with capacitive loads | 5000 µF |
residual ripple | < 120 mV |
Expected capacitor life time | 10 year(s) |
meantime between failure [MTBF] | 700000 h at 25 °C, full load conforming to SR 332 |
output protection type | Against overload and short-circuits, protection technology: automatic reset Against over temperature, protection technology: manual reset Against overvoltage, protection technology: manual reset |
connections – terminals | Screw connection: 0.5…2.5 mm², (AWG 20…AWG 14) for output Screw connection: 0.75…2.5 mm², (AWG 18…AWG 14) for input |
line and load regulation | < 0.5 % network 0 to 100 % load at 25 °C < 1 % network full voltage range in line at 25 °C |
status LED | 1 LED (green) output voltage |
depth | 102 mm |
height | 123.6 mm |
width | 27 mm |
net weight | 0.22 kg |
output coupling | Parallel Serial |
mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 Double-profile DIN rail |
supply | SELV conforming to EN/IEC 60950-1 SELV conforming to EN/IEC 60204-1 SELV conforming to IEC 60364-4-41 |
dielectric strength | 3000 V AC with input to output |
standards | EN 62368-1 EN/IEC 61010-1 EN 61010-2-201 EN/IEC 61204-3 EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 EN 61000-3-2 EN 61000-3-3 UL 62368-1 UL 61010-1 UL 61010-2-201 CSA C22.2 No 62368-1 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 EN/IEC 62368-1 |
---|---|
product certifications | CE CUL listed CUL recognized RCM CB Scheme EAC KC NEC: class 2 |
environmental characteristic | 3M4 conforming to IEC 60721-3-3 |
operating altitude | < 5000 m |
shock resistance | 100 m/s² for 11 ms |
IP degree of protection | IP20 |
Ambient air temperature for operation | -20…-10 °C with current derating of 1 % per °C mounting position A < 2000 m -10…40 °C without derating mounting position A 115 V AC < 2000 m -10…50 °C without derating mounting position A 230 V AC < 2000 m 40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 2000 m 50…70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 2000 m |
electrical shock protection class | Class I |
pollution degree | 2 |
vibration resistance | 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6 10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6 |
Electromagnetic immunity | Immunity to electrostatic discharge – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Immunity to electrostatic discharge – test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2 Immunity to conducted RF disturbances – test level: 10 V/m (80 MHz…2 GHz) conforming to EN/IEC 61000-4-3 Immunity to conducted RF disturbances – test level: 5 V/m (2…2.7 GHz) conforming to EN/IEC 61000-4-3 Immunity to conducted RF disturbances – test level: 3 V/m (2.7…6 GHz) conforming to EN/IEC 61000-4-3 Immunity to fast transients – test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4 Surge immunity test – test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5 Surge immunity test – test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5 Immunity to conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 Immunity to magnetic fields – test level: 30 A/m (50…60 Hz) conforming to EN/IEC 61000-4-8 Immunity to voltage dips conforming to EN/IEC 61000-4-11 Disturbing field emission conforming to EN 55016-2-3 Limits for harmonic current emissions conforming to EN 61000-3-2 Conducted disturbance emission conforming to EN 55016-1-2 Conducted disturbance emission conforming to EN 55016-2-1 |
electromagnetic emission | Conducted emissions conforming to EN 61000-6-3 Radiated emissions conforming to EN 61000-6-4 |
Unit Type of Package 1 | PCE |
---|---|
Package 1 Length | 16.0 cm |
Number of Units in Package 1 | 1 |
Package 3 Width | 80.0 cm |
Package 3 Weight | 192.6 kg |
Package 2 Width | 30.0 cm |
Package 2 Height | 30.0 cm |
Package 2 Weight | 7.283 kg |
Number of Units in Package 3 | 528 |
Unit Type of Package 3 | P12 |
Package 3 Height | 105.0 cm |
Package 3 Length | 120.0 cm |
Package 1 Width | 14.0 cm |
Package 1 Height | 3.7 cm |
Package 1 Weight | 303.0 g |
Number of Units in Package 2 | 22 |
Unit Type of Package 2 | S03 |
Package 2 Length | 40.0 cm |