Industrial Controls & Automation

View cart “ATV320U22N4C DRIVE 3 HP 440V / 3 PHASES” has been added to your cart.

ATV320U04M2C DRIVE 1/2 HP 240V / 1 PHASE

ATV320U04M2C AC DRIVE 1/2 HP 200..240 VAC 1 PHASE

Variable speed drive, ATV320, 0.37 kW, compact.

$295.00

Available on backorder

ATV320U04M2C AC DRIVE 1/2 HP 200..240 VAC 1 PHASE

Main
range of product
Altivar Machine ATV320
Product or component type
Variable speed drive
Product-specific application
Complex machines
variant
Standard version
format of the drive
Compact
Mounting mode
Wall mount
Communication port protocol
Modbus serial
CANopen
option card
Communication module, CANopen
Communication module, EtherCAT
Communication module, Profibus DP V1
Communication module, Profinet
Communication module, Ethernet Powerlink
Communication module, EtherNet/IP
Communication module, DeviceNet
[Us] rated supply voltage
200…240 V – 15…10 %
nominal output current
3.3 A
motor power kW
0.37 kW for heavy duty
EMC filter
Class C2 EMC filter integrated
IP degree of protection
IP20
Complementary
discrete input number
7
discrete input type
STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1…DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
discrete input logic
Positive logic (source)
Negative logic (sink)
discrete output number
3
discrete output type
Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
analogue input number
3
analogue input type
AI1 voltage: 0…10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0…20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
analogue output number
1
analogue output type
Software-configurable current AQ1: 0…20 mA impedance 800 Ohm, resolution 10 bits
Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits
relay output type
Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
maximum switching current
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
minimum switching current
Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
method of access
Slave CANopen
4 quadrant operation possible
True
asynchronous motor control profile
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio – Energy Saving, quadratic U/f
Flux vector control without sensor – Energy Saving
Voltage/frequency ratio, 2 points
synchronous motor control profile
Vector control without sensor
maximum output frequency
0.599 kHz
transient overtorque
170…200 % of nominal motor torque
acceleration and deceleration ramps
Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
motor slip compensation
Automatic whatever the load
Adjustable 0…300 %
Not available in voltage/frequency ratio (2 or 5 points)
switching frequency
2…16 kHz adjustable
4…16 kHz with derating factor
nominal switching frequency
4 kHz
braking to standstill
By DC injection
brake chopper integrated
True
line current
5.9 A at 200 V (heavy duty)
4.9 A at 240 V (heavy duty)
Maximum input current
5.9 A
maximum output voltage
240 V
apparent power
1.2 kVA at 240 V (heavy duty)
Network frequency
50…60 Hz
relative symmetric network frequency tolerance
5 %
prospective line Isc
1 kA
base load current at high overload
3.7 A
power dissipation in W
Self-cooled: 30 W at 200 V, switching frequency 4 kHz
with safety function Safely Limited Speed (SLS)
True
with safety function Safe brake management (SBC/SBT)
False
with safety function Safe Operating Stop (SOS)
False
with safety function Safe Position (SP)
False
with safety function Safe programmable logic
False
with safety function Safe Speed Monitor (SSM)
False
with safety function Safe Stop 1 (SS1)
True
with sft fct Safe Stop 2 (SS2)
False
with safety function Safe torque off (STO)
True
with safety function Safely Limited Position (SLP)
False
with safety function Safe Direction (SDI)
False
protection type
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drive
Width
72.0 mm
Height
143.0 mm
Depth
128.0 mm
Net weight
1 kg
Environment
operating position
Vertical +/- 10 degree
Product certifications
CE
ATEX
NOM
GOST
EAC
RCM
KC
marking
CE
ATEX
UL
CSA
EAC
RCM
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
environmental class (during operation)
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
maximum acceleration under vibrational stress (during operation)
10 m/s² at 13…200 Hz
maximum deflection under vibratory load (during operation)
1.5 mm at 2…13 Hz
permitted relative humidity (during operation)
Class 3K5 according to EN 60721-3
overvoltage category
III
regulation loop
Adjustable PID regulator
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
pollution degree
2
ambient air transport temperature
-25…70 °C
ambient air temperature for operation
-10…50 °C without derating
50…60 °C with derating factor
Ambient air temperature for storage
-25…70 °C
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
1.181 kg
Package 1 Height
11.5 cm
Package 1 width
18.7 cm
Package 1 Length
19 cm
Unit Type of Package 2
P06
Number of Units in Package 2
45
Package 2 Weight
66.15 kg
Package 2 Height
80 cm
Package 2 width
80 cm
Package 2 Length
60 cm
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free
Yes
RoHS exemption information
China RoHS Regulation
Environmental Disclosure
Circularity Profile