| Motor power kW |
2.2 kW at 220…230 V AC 50/60 Hz (AC-3)
4 kW at 380…400 V AC 50/60 Hz (AC-3)
4 kW at 415…440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660…690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
2.2 kW at 220…230 V AC 50/60 Hz (AC-3e)
4 kW at 380…400 V AC 50/60 Hz (AC-3e)
4 kW at 415…440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660…690 V AC 50/60 Hz (AC-3e) |
| Maximum Horse Power Rating |
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phase motors
2 hp at 230/240 V AC 50/60 Hz for 3 phase motors
5 hp at 460/480 V AC 50/60 Hz for 3 phase motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors |
| Compatibility code |
LC1D |
| Pole contact composition |
3 NO |
| Protective cover |
With |
| [Ith] conventional free air thermal current |
25 A (at 140.0000000000 °F (60 °C)) for power circuit
10 A (at 140.0000000000 °F (60 °C)) for signalling circuit |
| Irms rated making capacity |
250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity |
250 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current |
105 A 104.0000000000 °F (40 °C) – 10 s for power circuit
210 A 104.0000000000 °F (40 °C) – 1 s for power circuit
30 A 104.0000000000 °F (40 °C) – 10 min for power circuit
61 A 104.0000000000 °F (40 °C) – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit |
| Associated fuse rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance |
2.5 mOhm – Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole |
1.56 W AC-1
0.2 W AC-3
0.2 W AC-3e |
| [Ui] rated insulation voltage |
Power circuit 690 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL |
| Overvoltage category |
III |
| Pollution degree |
3 |
| [Uimp] rated impulse withstand voltage |
6 kV IEC 60947 |
| Safety reliability level |
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
| Mechanical durability |
15 Mcycles |
| Electrical durability |
0.6 Mcycles 25 A AC-1 <= 440 V
2 Mcycles 9 A AC-3 <= 440 V
2 Mcycles 9 A AC-3e <= 440 V |
| Control circuit type |
AC 50/60 Hz standard |
| Coil technology |
Without built-in suppressor module |
| Control circuit voltage limits |
0.3…0.6 Uc -40.0000000000…158.0000000000 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 50 Hz
0.85…1.1 Uc -40.0000000000…140.0000000000 °F (-40…60 °C) operational AC 60 Hz
1…1.1 Uc 140.0000000000…158.0000000000 °F (60…70 °C) operational AC 50/60 Hz |
| Inrush power in VA |
70 VA 60 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C))
70 VA 50 Hz cos phi 0.75 (at 68.0000000000 °F (20 °C)) |
| Hold-in power consumption in VA |
7.5 VA 60 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C))
7 VA 50 Hz cos phi 0.3 (at 68.0000000000 °F (20 °C)) |
| Heat dissipation |
2…3 W at 50/60 Hz |
| Operating time |
12…22 ms closing
4…19 ms opening |
| Maximum operating rate |
3600 cyc/h 140.0000000000 °F (60 °C) |
| Maximum operating rate |
3600 cyc/h at 60 °C |
| Connections – terminals |
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end |
| Tightening torque |
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 |
| Auxiliary contact composition |
1 NO + 1 NC |
| Auxiliary contacts type |
Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1 |
| Signalling circuit frequency |
25…400 Hz |
| Minimum switching voltage |
17 V for signalling circuit |
| Minimum switching current |
5 mA for signalling circuit |
| Insulation resistance |
> 10 MOhm for signalling circuit |
| Non-overlap time |
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact |
| Mounting Support |
Rail
Plate |