LC1F225M7

LC1F225M7 – TeSys F Contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 220 VAC.

$950.00

Main
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Motor control
Resistive load
utilisation category
AC-1
AC-4
AC-3
poles description
3P
power pole contact composition
3 NO
[Ue] rated operational voltage
<= 460 V DC
<= 690 V AC 50/60 Hz
[Ie] rated operational current
315 A (at <40 °C) at <= 440 V AC-1
225 A (at <55 °C) at <= 440 V AC-3
motor power kW
110 kW at 380…400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660…690 V AC 50/60 Hz (AC-3)
63 kW at 220…230 V AC 50/60 Hz (AC-3)
40 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage
220 V AC 40…400 Hz
Complementary
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
315 A (at 40 °C)
rated breaking capacity
1800 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
1800 A 40 °C – 10 s
1000 A 40 °C – 30 s
850 A 40 °C – 1 min
560 A 40 °C – 3 min
440 A 40 °C – 10 min
associated fuse rating
315 A gG at <= 440 V
250 A aM at <= 440 V
average impedance
0.32 mOhm – Ith 315 A 50 Hz
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole
32 W AC-1
16 W AC-3
mounting support
Plate
standards
IEC 60947-1
JIS C8201-4-1
EN 60947-1
IEC 60947-4-1
EN 60947-4-1
product certifications
RINA
BV
CSA
UL
LROS (Lloyds register of shipping)
DNV
RMRoS
ABS
CB
connections – terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) – busbar cross section: 32 x 4 mm
Power circuit: lugs-ring terminals 1 cable(s) 185 mm²
Power circuit: connector 1 cable(s) 185 mm²
Power circuit: bolted connection
tightening torque
Control circuit: 1.2 N.m
Power circuit: 35 N.m
control circuit voltage limits
Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C)
Drop-out: 0.35…0.55 Uc 40…400 Hz (at 55 °C)
inrush power in VA
1070 VA 40…400 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA
9.9 VA 40…400 Hz cos phi 0.9 (at 20 °C)
heat dissipation
8…9.8 W
operating time
35 ms closing (at Uc)
130 ms opening (at Uc)
mechanical durability
10 Mcycles
maximum operating rate
2400 cyc/h 55 °C
compatibility code
LC1F
motor power range
55…100 kW at 200…240 V 3 phases
110…220 kW at 480…500 V 3 phases
110…220 kW at 380…440 V 3 phases
motor starter type
Direct on-line contactor
contactor coil voltage
220 V AC standard