Industrial Controls & Automation

LC1G500LSEA

LC1G500LSEA Contactor High Power Tesys Giga 3 Pole/NO. AC 3 500A 200-500VAC/DC Coil

Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 500A, 200-500VAC/DC coil

$2,250.00

LC1G500LSEA Contactor, high power, TeSys Giga, advanced version, 3 pole/NO, AC-3 <=440V 500A, 200-500VAC/DC coil

TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 500A 315kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.

Specifications

Main
Range TeSys
Range of Product TeSys Giga
Product or Component Type Contactor
Device short name LC1G
contactor application Power switching
Motor control
Utilisation category AC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8b
AC-8a
DC-1
DC-3
DC-5
poles description 3P
[Ue] rated operational voltage <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current 700 A (at <104.0000000000 °F (40 °C)) at <= 1000 V AC-1
500 A (at <140.0000000000 °F (60 °C)) at <= 440 V AC-3
[Uc] control circuit voltage 200…500 V AC 50/60 Hz
200…500 V DC
Control circuit voltage limits Operational: 0.8 Uc Min…1.1 Uc Max (at <140.0000000000 °F (60 °C))
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <140.0000000000 °F (60 °C))
Complementary
[Uimp] rated impulse withstand voltage 8 kV
Overvoltage category III
Rated breaking capacity 4600 A at 440 V
[Icw] rated short-time withstand current 4.0 kA – 10 s
2.8 kA – 30 s
2.2 kA – 1 min
1.5 kA – 3 min
1.2 kA – 10 min
Associated fuse rating 500 A aM at <= 440 V for motor
400 A aM at <= 690 V for motor
800 A gG at <= 690 V
Average impedance 0.00008 Ohm
[Ui] rated insulation voltage 1000 V
Power dissipation per pole 40 W AC-1 – Ith 700 A
20 W AC-3 – Ith 500 A
Compatibility code LC1G
Pole contact composition 3 NO
Auxiliary contact composition 1 NO + 1 NC
Motor power kW 147 kW at 230 V AC 50/60 Hz (AC-3e)
250 kW at 400 V AC 50/60 Hz (AC-3e)
250 kW at 415 V AC 50/60 Hz (AC-3e)
280 kW at 440 V AC 50/60 Hz (AC-3e)
315 kW at 500 V AC 50/60 Hz (AC-3e)
355 kW at 690 V AC 50/60 Hz (AC-3e)
335 kW at 1000 V AC 50/60 Hz (AC-3e)
160 kW at 230 V AC 50/60 Hz (AC-3)
250 kW at 400 V AC 50/60 Hz (AC-3)
250 kW at 415 V AC 50/60 Hz (AC-3)
315 kW at 440 V AC 50/60 Hz (AC-3)
355 kW at 500 V AC 50/60 Hz (AC-3)
355 kW at 690 V AC 50/60 Hz (AC-3)
335 kW at 1000 V AC 50/60 Hz (AC-3)
150 kW at 230 V AC 50/60 Hz (AC-4)
250 kW at 400 V AC 50/60 Hz (AC-4)
250 kW at 415 V AC 50/60 Hz (AC-4)
295 kW at 440 V AC 50/60 Hz (AC-4)
295 kW at 500 V AC 50/60 Hz (AC-4)
355 kW at 690 V AC 50/60 Hz (AC-4)
280 kW at 1000 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating 150 hp at 200/208 V 60 Hz
200 hp at 230/240 V 60 Hz
400 hp at 460/480 V 60 Hz
450 hp at 575/600 V 60 Hz
Coil technology Built-in bidirectional peak limiting
Safety reliability level B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 8 Mcycles
inrush power in VA (50/60 Hz, AC) 535 VA
inrush power in W (DC) 300 W
hold-in power consumption in VA (50/60 Hz, AC) 15.4 VA
hold-in power consumption in W (DC) 8.6 W
Operating time 40…70 ms closing
15…50 ms opening
Maximum operating rate 600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Connections – terminals Power circuit: bar 2 – busbar cross section: 32 x 10 mm
Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²)
Power circuit: bolted connection
Control circuit: push-in 1 0.0003…0.004 in² (0.2…2.5 mm²) – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.0004…0.004 in² (0.25…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.0008…0.002 in² (0.5…1.0 mm²) with cable end
Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.001…0.004 in² (0.75…2.5 mm²) – cable stiffness: flexible with cable end
Connection pitch 1.8 in (45 mm)
Mounting Support Plate
Standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ
Product Certifications CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque 309.8 lbf.in (35 N.m)
Height 11.4 in (290 mm)
Width 5.5 in (140 mm)
Depth 8.9 in (226 mm)
Net Weight 18.08 lb(US) (8.2 kg)
Environment
IP degree of protection IP2X front face with shrouds IEC 60529
IP2X front face with shrouds VDE 0106
Ambient Air Temperature for Operation -13.0000000000…140.0000000000 °F (-25…60 °C)
Ambient Air Temperature for Storage -76.0000000000…176.0000000000 °F (-60…80 °C)
Mechanical robustness Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
color Dark grey
Protective treatment TH
Permissible ambient air temperature around the device -40.0000000000…158.0000000000 °F (-40…70 °C) at Uc
Ordering and shipping details
Category US10I1222329
Discount Schedule 0I12
GTIN 3606481922496
Returnability Yes
Country of origin CN