Industrial Controls & Automation

View cart “6EP3331-6SB00-0AY0 LOGO! Power 24V / 1.3A” has been added to your cart.
ABLS1A24200

ABLS1A24200 Regulated Power Supply, 100-240V AC, 24V 20 A, single phase, Optimized

ABLS1A24200

Regulated Power Supply, 100-240V AC, 24V 20 A, single phase, Optimized. Brand: Schneider Electric. Miami Florida. In Stock.

$238.00

ABLS1A24200

Main
range of product Modicon Power Supply
product or component type Power supply
power supply type Regulated switch mode
variant option Optimized
enclosure material Aluminium
Nominal input voltage 100…240 V AC single phase
100…240 V AC 2 phases
140…340 V DC
rated power in W 480 W
output voltage 24 V DC
power supply output current 20 A
Complementary
Input voltage limits 85…264 V AC (without temperature derating)
120…375 V DC (without temperature derating)
85…120 V DC (with temperature derating)
85…120 V DC
Nominal network frequency 50…60 Hz
Network system compatibility TN
TT
IT
maximum leakage current 1 mA 240 V AC
input protection type Integrated fuse (not interchangeable) 10 A
External protection (recommended) 20 A Curve C
External protection (recommended) 16 A Curve B
External protection (recommended) 13 A Curve C
inrush current 45.0 A at 115 V
90.0 A at 230 V
power factor 0.95 at 115 V AC
0.95 at 230 V AC
efficiency 85 % at 115 V AC
88 % at 230 V AC
Output voltage adjustment 22…28 V
power dissipation in W 60 W
current consumption < 5.4 A 115 V AC
< 2.7 A 230 V AC
< 5 A 140 V DC
Turn-on time < 1.5 s
holding time > 20 ms 115 V AC
> 20 ms 230 V AC
Startup with capacitive loads 8000 µF
residual ripple < 120 mV
Expected capacitor life time 10 year(s)
meantime between failure [MTBF] 700000 h at 25 °C, full load conforming to SR 332
output protection type Against overload and short-circuits, protection technology: automatic reset
Against over temperature, protection technology: manual reset
Against overvoltage, protection technology: manual reset
connections – terminals Screw connection: 0.5…4 mm², (AWG 20…AWG 12) without wire end ferrule for output
Screw connection: 0.5…2.5 mm², (AWG 20…AWG 14) with wire end ferrule for output
Screw connection: 0.75…4 mm², (AWG 18…AWG 12) without wire end ferrule for input
Screw connection: 0.75…4 mm², (AWG 18…AWG 12) with wire end ferrule for input
line and load regulation < 0.5 % network 0 to 100 % load at 25 °C
< 1 % network full voltage range in line at 25 °C
status LED 1 LED (green) output voltage
depth 128.5 mm
height 123.6 mm
width 85.5 mm
net weight 1.25 kg
output coupling Parallel
Serial
mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Double-profile DIN rail
supply SELV conforming to EN/IEC 60950-1
SELV conforming to EN/IEC 60204-1
SELV conforming to IEC 60364-4-41
dielectric strength 3000 V AC with input to output
Environment
standards EN 62368-1
EN/IEC 61010-1
EN 61010-2-201
EN/IEC 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3-2
EN 61000-3-3
UL 62368-1
UL 61010-1
UL 61010-2-201
CSA C22.2 No 62368-1
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
EN/IEC 62368-1
product certifications CE
CUL listed
CUL recognized
RCM
CB Scheme
EAC
KC
environmental characteristic 3M4 conforming to IEC 60721-3-3
operating altitude < 5000 m
shock resistance 100 m/s² for 11 ms
IP degree of protection IP20
Ambient air temperature for operation -20…40 °C without derating mounting position A 115 V AC < 2000 m
-20…50 °C without derating mounting position A 230 V AC < 2000 m
40…70 °C with current derating of 1.67 % per °C mounting position A 115 V AC < 2000 m
50…70 °C with current derating of 2.5 % per °C mounting position A 230 V AC < 2000 m
electrical shock protection class Class I
pollution degree 2
vibration resistance 3 mm (f= 2…9 Hz) conforming to IEC 60068-2-6
10 m/s² (f= 9…200 Hz) conforming to IEC 60068-2-6
Electromagnetic immunity Immunity to electrostatic discharge – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Immunity to electrostatic discharge – test level: 9 kV (air discharge) conforming to EN/IEC 61000-4-2
Immunity to conducted RF disturbances – test level: 10 V/m (80 MHz…2 GHz) conforming to EN/IEC 61000-4-3
Immunity to conducted RF disturbances – test level: 5 V/m (2…2.7 GHz) conforming to EN/IEC 61000-4-3
Immunity to conducted RF disturbances – test level: 3 V/m (2.7…6 GHz) conforming to EN/IEC 61000-4-3
Immunity to fast transients – test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
Surge immunity test – test level: 3 kV (between power supply and earth) conforming to EN/IEC 61000-4-5
Surge immunity test – test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
Immunity to conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6
Immunity to magnetic fields – test level: 30 A/m (50…60 Hz) conforming to EN/IEC 61000-4-8
Immunity to voltage dips conforming to EN/IEC 61000-4-11
Disturbing field emission conforming to EN 55016-2-3
Limits for harmonic current emissions conforming to EN 61000-3-2
Conducted disturbance emission conforming to EN 55016-1-2
Conducted disturbance emission conforming to EN 55016-2-1
electromagnetic emission Conducted emissions conforming to EN 61000-6-3
Radiated emissions conforming to EN 61000-6-4
Packing Units
Unit Type of Package 1 PCE
Package 1 Length 18.0 cm
Number of Units in Package 1 1
Package 2 Width 30 cm
Package 2 Height 30 cm
Package 2 Weight 10.517 kg
Package 3 Height 90 cm
Package 1 Width 17.5 cm
Package 1 Height 9.5 cm
Package 1 Weight 1.419 kg
Number of Units in Package 2 7
Unit Type of Package 2 S03
Package 2 Length 40 cm